6.11.5 Instantiating AXIS_REF_DDS in Automation Studio™
Procedure
1. Create 1 instance of function block
AXIS_REF_DDS
(located in folder
DDS_Drive
) for every SDM 511/SDM 512 drive module and
servo drive that has to be controlled or monitored.
2. To create a link to the physical servo drive, link each instance of
AXIS_REF_DDS
to 1 physical servo drive. This makes it the logical
representation of 1 physical servo drive.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
Initialize each instance of a drive with its
DriveType
.
Example:
Illustration 63: Instantiation of AXIS_REF_DDS and Setting of Initial Values
6.11.6 Instantiating PSM_REF in Automation Studio™
Procedure
1. Create 1 instance of function block
PSM_REF
(located in folder
DDS_PSM
) for every Power Supply Module (PSM) that has to be
controlled or monitored.
2. To create a link to the physical PSM, link each instance of
PSM_REF
to 1 physical PSM. This makes it the logical representation of 1
physical PSM.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
90 | Danfoss A/S © 2019.10