Table 26: Operating LEDs on DAM 510
LED
Color
Flash status
Description
DEV
Green
On
Device is in state
Operation enabled
.
Flashing
Device is in state
Standby
or
Power-up
.
Red
On
Device is in state
Fault
or
Fault reaction active
.
Flashing
DC-link is not applied at the input.
SVS ST
Green
On
24 V safety supply is applied.
Off
24 V safety supply is not applied.
NET ST
Green
On
Connected.
Orange
On
Online.
Red
Flashing
Initialization.
On
Initialization failed or other error.
AUX
(State of the auxiliary voltage)
Green
On
Auxiliary voltage is applied to the output connector.
Off
Auxiliary voltage is not applied to the output connector.
Red
On
Auxiliary voltage undervoltage detected in the hardware.
LINK/ACT X1
(Link/activity of
In
)
Green
On
Ethernet link established.
Flashing
Ethernet link established and active.
Off
No link.
LINK/ACT X2
(Link/activity status of
Hybrid Out
)
Green
On
Ethernet link established.
Flashing
Ethernet link established and active.
Off
No link.
LINK/ACT X3
(Link/activity status of
Out
)
Green
On
Ethernet link established.
Flashing
Ethernet link established and active.
Off
No link.
Operation
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 151
Danfoss A/S © 2019.10