![Danfoss VLT MSD 510 Скачать руководство пользователя страница 229](http://html1.mh-extra.com/html/danfoss/vlt-msd-510/vlt-msd-510_operating-manual_3872583229.webp)
e3
0b
g4
54
.1
1
1
2
Illustration 145: STO Output Connector on PSM 510
e3
0b
h6
64
.1
0
3
4
Illustration 146: STO Input Connector on PSM 510
Table 148: Pin Assignment of STO Connectors on PSM 510
Connec‐
tor
name
Pins
De‐
scrip‐
tion
Notes
Rating/parameter
STO PSM
1
STO–
Used for STO output
voltage to the input
of the other system
modules.
Nominal voltage: 24 V DC ±10%
Nominal current: Depends on the number of servo drives in the applica-
tion.
Maximum current: 1 A
Conductor cross-section range: 0.2–1.5 mm
2
(AWG 24–AWG 16)
2
STO+
3
STO–
Used for STO input
voltage.
4
STO+
Specifications
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 229