6.11.10.1 Version V3.0.90
Procedure
1. Select the menu entry [Tools
→
Import Fieldbus Device...].
2. Select the XDD file for the PSM 510, DAM 510, or ACM 510 from its location on the hard drive. This import only needs to be done
once per project. The device is then known to Automation Studio™.
Power Supply Module (PSM 510):
0x0300008D_PSM.xdd
Decentral Access Module (DAM 510):
0x0300008D_DAM.xdd
Auxiliary Capacitors Module (ACM 510):
0x0300008D_ACM.xdd
3. Now add the PSM 510, DAM 510, or ACM 510 to the Ethernet POWERLINK
®
interface of the controller in the
Physical View
:
Right-click on the controller in the
Physical View
and select [Open POWERLINK].
Right-click on the interface and select
Insert...
.
In the
Select controller module
window, select the PSM 510, DAM 510, or ACM 510 in the group
POWERLINK Devices
.
Click on
Next
.
In the next window, enter the node number of the PSM 510, DAM 510, or ACM 510.
e3
0b
h5
15
.1
0
Illustration 66: 1 PSM 510, 1 DAM 510, and 2 ISD 510 Servo Drives Added to the Ethernet POWERLINK
®
Interface in V3.0.90
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
94 | Danfoss A/S © 2019.10