WARNING
DISCHARGE TIME
The MSD 510 system contains DC-link capacitors that remain charged for some time after the mains supply is switched off at
the Power Supply Module (PSM 510). Failure to wait the specified time after power has been removed before performing
service or repair work could result in death or serious injury.
-
To avoid electrical shock, fully disconnect the Power Supply Module (PSM 510) from the mains and wait for the capacitors
to fully discharge before carrying out any maintenance or repair work on the servo system or its components.
Minimum waiting time (minutes)
15
DANGER
-
Risque du choc électrique. Une tension dangereuse peut être présentée jusqu’à 15 min après avoir coupé l’alimentation.
WARNING
UNINTENDED START
The MSD 510 system contains servo drives, the PSM 510, and DAM 510 that are connected to the electrical supply network and
can start running at any time. This may be caused by a fieldbus command, a reference signal, or clearing a fault condition. Servo
drives and all connected devices must be in good operating condition. A deficient operating condition may lead to death,
serious injury, damage to equipment, or other material damage when the unit is connected to the electrical supply network.
-
Take suitable measures to prevent unintended starts.
WARNING
UNINTENDED MOVEMENT
Unintended movement may occur when parameter changes are carried out immediately, which may result in death, serious
injury, or damage to equipment.
-
When changing parameters, take suitable measures to ensure that unintended movement cannot pose any danger.
CAUTION
DANGER OF BURNS
The surface of the servo drives can reach high temperatures of over 90°C during operation.
-
Do not touch the servo drives until they have cooled down.
Safety
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
20 | Danfoss A/S © 2019.10
Содержание VLT MSD 510
Страница 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Страница 2: ......