![Danfoss VLT MSD 510 Скачать руководство пользователя страница 227](http://html1.mh-extra.com/html/danfoss/vlt-msd-510/vlt-msd-510_operating-manual_3872583227.webp)
21
22
23
e3
0b
h6
63
.1
0
Illustration 143: Relay Connector for SDM 511 Enclosure Size 2 (FS2)
Table 146: Pin Assignment of Relay Connector on SDM 511/SDM 512
Name
Pins
Description
Notes
Rating/parameter
REL SDM1
11
NC
Normally closed, 24 V DC
Nominal current: 2 A
Conductor cross-section range: 0.2–1.5 mm
2
(AWG 24–AWG 16)
12
NO
Normally open, 24 V DC
13
COM
Common
REL SDM2
(1)
21
NC
Normally closed, 24 V DC
22
NO
Normally open, 24 V DC
23
COM
Common
1
Only on SDM 512.
11.7.10 STO Connectors
11.7.10.1 STO Connectors on SDM 511 and SDM 512
The STO connectors are located on the Servo Drive Modules as follows:
•
SDM 511: 1 input and 1 output STO connector
•
SDM 512: 2 input and 2 output STO connectors
Specifications
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 227
Danfoss A/S © 2019.10
Содержание VLT MSD 510
Страница 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Страница 2: ......