Illustration 138: LCP Connector (M8, 6 pole)
Table 139: Pin Assignment of LCP Connector
Pins
Description
Notes
Rating/parameter
1
Not connected
–
–
2
/LCP RST
Reset
Active at
≦
0.5 V
3
LCP RS485
Positive RS485 signal
Speed:
38.4 kBd
The levels fulfill the RS485 specification.
4
/LCP RS485
Negative RS485 signal
5
GND
GND
–
6
VCC
5 V supply for LCP
5 V ±10% at 120 mA maximum load
NOTICE
-
Only PELV potential can be connected to the LCP input.
11.7.7 AC Mains Connector
The AC mains connector is located on the bottom of the Power Supply Module (PSM 510).
e
3
0
b
g
4
5
2
.1
0
Illustration 139: AC Mains Connector
Specifications
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 223
Danfoss A/S © 2019.10