9.3.77 Firmware: Update started (0xFF72 / 0x11D)
This error is valid for PSM 510, DAM 510, ACM 510, and SDM 511/SDM 512.
Table 112: Firmware: Update started (0xFF72 / 0x11D)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF72
0x11D
Firmware: Up-
date started
Warning, error
Firmware update is in progress.
Warning changes to error when an attempt is
made to enable the device in this state.
FW update
9.3.78 Firmware: Update invalid (0xFF73 / 0x15B)
This error is valid for PSM 510 and DAM 510.
Table 113: Firmware: Update invalid (0xFF73 / 0x15B)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF73
0x15B
Firmware: Up-
date invalid
Error
Invalid or corrupted firmware package
update.
Last valid firmware package has been loa-
ded.
FW upd invalid
9.3.79 STO active while drive enabled (0xFF80 / 0x11E)
This error is valid for SDM 511/SDM 512.
Table 114: STO active while drive enabled (0xFF80 / 0x11E)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0xFF80
0x11E
STO active while
drive enabled
Error
STO activated while drive was enabled
or tried to enable while STO active.
STO active
9.3.80 STO mismatch (0xFF81 / 0x11F)
This error is valid for SDM 511/SDM 512.
Table 115: STO mismatch (0xFF81 / 0x11F)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0xFF81
0x11F
STO mis-
match
Trip lock
Dual diagnosis of STO voltage not
plausible.
STO mismatch
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
190 | Danfoss A/S © 2019.10
Содержание VLT MSD 510
Страница 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Страница 2: ......