Procedure
1. Select
Library TxPDO
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT)
→
Box 1 (VLT Decentral Access Module)
→
Drive 1 (VLT ISD 510 Integrated Servo Drive)
→
Module 1 (Library PDO)
→
Library TxPDO].
2. Select all entries
Lib pdo tx1
to
Lib pdo tx9
on the right side of the window.
e3
0b
h5
19
.1
0
Illustration 78: Attaching Inputs and Outputs to the Physical Data Points
3. Right-click and select
Change Multi Link...
.
4. In the
Attach Variable 36.0 Byte(s) (Input)
window, select [PLC-Configuration
→
MyFirstFlexMotionProject
→
Standard
→
.myAxis.TPDO]. Ensure that the
Matching Size
option is selected in the
Attach Variable
window.
5. Click on
OK
.
6. Click on library
RxPDO
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT™)
→
Box1 (VLT™ Decentral Access
Module)
→
Drive2 (VLT™ ISD 510 Integrated Servo Drive)
→
Module1 (Library PDO)
→
Library RxPDO].
7. Select all entries
Lib pdo rx1
to
Lib pdo rx9
on the right side of the window.
8. Right-click and select
Change Multi Link...
.
9. In the
Attach Variable 36.0 Byte(s) (Output)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.RPDO].
10. Click on
OK
.
11. Right-click on
WcState
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT™)
→
Box1 (VLT™ Decentral Access
Module)
→
Drive2 (VLT™ ISD 510 Integrated Servo Drive)
→
WcState] and select
Change Link...
.
12. In the
Attach Variable State (Input)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.WcState].
13. Click on
OK
.
14. Right-click on
State
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT™)
→
Box1 (VLT™ Decentral Access Module)
→
Drive2 (VLT™ ISD 510 Integrated Servo Drive)
→
InfoData] and select
Change Link...
.
15. In the
Attach Variable State (Input)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.State].
16. Click on
OK
.
17. Right-click on
netId
via menu [I/O-Configuration
→
I/O Devices Device1 (EtherCAT
→
)
→
Box1 (VLT
®
Decentral Access Module)
→
Drive2 (VLT
→
ISD 510 Integrated Servo Drive)
→
InfoData
→
AdsAddr] and select
Change Link...
.
18. In the
Attach Variable netId (Input)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.AmsNetId].
19. Click on
OK
.
20. Right-click on
Port
via [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT
→
)
→
Box1 (VLT
→
Decentral Access Module)
→
Drive2 (VLT
→
ISD 510 Integrated Servo Drive)
→
InfoData
→
AdsAddr] and select
Change Link...
.
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 109