6.11.3 Including the Servo Motion Libraries into an Automation Studio™ Project
Procedure
1. In the
Logical View
, open the menu entry [File
→
Import...].
2. In the next window, select the Danfoss_VLT_ServoMotion_V_x_y_z.zip file (according to the location on the hard drive).
3. Click on
Open
.
4. Assign the libraries to the CPU in the next window.
5. Click on
Finish
. Now the libraries are integrated into the Automation Studio™ project.
A new folder containing the ISD libraries is created during integration:
•
DDS_Drive
-
Contains program organization units (POUs) defined by PLCopen
®
(name starting with MC_) and POUs defined by Danfoss
(name starting with DD_). The Danfoss POUs provide additional functionality for the axis.
-
It is possible to combine POUs defined by PLCopen
®
with POUs defined by Danfoss.
-
The names of the POUs that target the servo drive all end with _DDS.
•
DDS_PSM
-
Contains POUs defined by Danfoss (name starting with DD_) and provide the functionality for the Power Supply Module
(PSM).
-
The names of the POUs that target the PSM all end with _PSM.
•
DDS_DAM
-
Contains POUs defined by Danfoss (name starting with DD_) and provide the functionality for the Decentral Access
Module (DAM).
-
The names of the POUs that target the DAM all end with _DAM.
•
DDS_ACM
-
Contains POUs defined by Danfoss (name starting with DD_) and provide the functionality for the Auxiliary Capacitors
Module (ACM).
-
The names of the POUs that target the ACM all end with _ACM.
•
DDS_BasCam
-
Contains POUs for the creation of basic CAMs.
•
DDS_LabCam
-
Contains POUs for the creation of labeling CAMs.
•
DDS_Intern
-
Contains POUs that are needed internally for the libraries.
-
Do not use these POUs in an application.
When integrating the DDS_Drive package, some standard libraries are integrated automatically, unless they are already part of
the project.
NOTICE
-
Do not remove these libraries otherwise the Danfoss servo motion libraries will not work.
6.11.4 Constants within the DDS_Drive Library
Inside the library, the following lists of constants are defined:
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
88 | Danfoss A/S © 2019.10