![Daikin RXL25G2V1B Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970075.webp)
SiENBE04-925_A
Operation Manual
Operation Manual
61
2.7
ECONO Operation
NOTE
ECONO operation is a function which enables efficient operation by
limiting the maximum power consumption value.
This function is useful for cases in which attention should be paid to
ensure a circuit breaker will not trip when the product runs alongside
other appliances.
To start ECONO operation
1. Press “ECONO button”.
•
“
” is displayed on the LCD.
To cancel ECONO operation
2. Press “ECONO button” again.
•
“
” disappears from the LCD.
•
This diagram is a representation for
illustrative purposes only.
*
The maximum running current and
power consumption of the air
conditioner in ECONO mode vary with
the connecting outdoor unit.
Notes on ECONO operation
•
ECONO Operation can only be set when the unit is running. Pressing the OFF button causes the setting to be canceled,
and the “
” disappears from the LCD.
•
ECONO operation is a function which enables efficient operation by limiting the power consumption of the outdoor unit
(operating frequency).
•
ECONO operation functions in AUTO, COOL, DRY and HEAT modes.
•
POWERFUL and ECONO operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
•
Power consumption may not drop even if ECONO operation is used of the level of power consumption is already low.
1, 2
Time
Running current and
power consumption
Normal operation
Maximum during
normal operation
Maximum during
ECONO Mode
From start up until set
temperature is reached
ECONO
Mode
SIENBE04-925_A_FRONT.pdf 75
24/02/2011 13:53:54
Содержание RXL25G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents ...
Страница 14: ...Introduction SiENBE04 925_A xii ...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications ...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356 ...