![Daikin RXL25G2V1B Скачать руководство пользователя страница 190](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970190.webp)
SiENBE04-925_A
Outdoor Unit - RXL20G2V1B
Removal Procedure
175
2.6
Removal of Reactor / Partition Plate
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the reactor.
Preparation
Remove the outer panels
according to the “Removal of
Outer Panels / Fan Motor”.
Remove the electrical box
according to the "Removal of
Electrical Box".
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
1
Remove the 2 screws.
(R7224)
Reactor
(R7225)
(R7226)
Partition plate