![Daikin RXL25G2V1B Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970046.webp)
Main Functions
SiENBE04-925_A
32
Function and Control
1.11 Other Functions
1.11.1 Hot-Start Function
In order to prevent the cold air blast that normally comes when heating operation is started, the
temperature of the indoor heat exchanger is detected, and either the airflow is stopped or is
made very weak thereby carrying out comfortable heating of the room.
*The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat is turned ON.
1.11.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote control, the unit emits a signal receiving
sound.
1.11.3 Indoor Unit ON/OFF Button
An ON/OFF button is provided on the display of the unit.
Press this button once to start operation. Press once again to stop it.
This button is useful when the remote control is missing or the battery has run out.
The operation mode refers to the following table.
<Forced operation mode>
Forced operation mode can be started by pressing the ON/OFF button for 5 to 9 seconds while
the unit is not operating.
Refer to "Forced operation mode" on page 48 for detail.
Note:
When the ON/OFF button is pressed for 10 seconds or more, the forced operation is stopped.
1.11.4 Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air-Purifying Filter and Titanium Apatite Photocatalytic Deodorizing
Filter as a single highly effective filter. The filter traps microscopic particles, decompose odors
and even deactivates bacteria and viruses. It lasts for 3 years without replacement if washed
about once every 6 months.
1.11.5 Auto-restart Function
Even if a power failure (including one for just a moment) occurs during the operation, the
operation restarts automatically when the power is restored in the same condition as before the
power failure.
Note:
It takes 3 minutes to restart the operation because the 3-minute standby function is activated.
1.11.6 WEEKLY TIMER Operation
Up to 4 timer settings can be saved for each day of the week (up to 28 settings in total).
Those 3 items of “ON/OFF”, “temperature” and “time” can be set.
Refer to “WEEKLY TIMER Operation” on page 63 for detail.
Mode
Temperature setting
Airflow rate
AUTO
25ºC
Automatic
(R8302)
ON/OFF button
SIENBE04-925_A_FRONT.pdf 46
24/02/2011 13:53:52
Содержание RXL25G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents ...
Страница 14: ...Introduction SiENBE04 925_A xii ...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications ...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356 ...