![Daikin RXL25G2V1B Скачать руководство пользователя страница 175](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970175.webp)
Outdoor Unit - RXL20G2V1B
SiENBE04-925_A
160
Removal Procedure
4
Disconnect the
connector for the fan
motor [S70].
5
Release the fan motor
lead wire from the hook.
6
Open the hooks and
release the fan motor
lead wire.
When reassembling, put the
fan motor lead wire through
the back of the fan motor (so
as not to be entangled with
the outdoor fan).
7
Remove the 4 screws
and remove the fan
motor.
Be sure to remove the lower
screws first. If the upper
screws are removed first, the
fan motor, the center of
gravity of which is toward the
front, may tilt down or fall,
getting you injured.
Step
Procedure
Points
(R9332)
[S70]
Fan motor
lead wire
(R7200)
(R7201)
(R3249)
Lead wire
Outdoor fan
Fan motor
(R7202)
SIENBE04-925_A_FRONT.pdf 175
24/02/2011 13:54:04
Содержание RXL25G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents ...
Страница 14: ...Introduction SiENBE04 925_A xii ...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications ...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356 ...