![Daikin RXL25G2V1B Скачать руководство пользователя страница 231](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970231.webp)
Outdoor Unit - RXL25G2V1B
SiENBE04-925_A
216
Removal Procedure
4.2
Removal of Electrical Box
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Disconnect the
connecting wires.
When reassembling, fasten
the wires with screws on the
terminal board.
1
Remove the 3 screws
to remove the wiring
fixture.
Then remove the all
screws to disconnect
the power supply
cables and the
connecting wires.
2. Remove the electrical
box.
1
Release the outdoor
temperature thermistor.
2
Remove the 7 screws,
and remove the right
side panel.
(R12192)
Wiring fixture
Power
supply
cable
Connecting
wire
Terminal
board
(R12289)
Outdoor temperature
thermistor
Right side panel
(R9365)