![Daikin RXL25G2V1B Скачать руководство пользователя страница 126](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970126.webp)
SiENBE04-925_A
Troubleshooting
Service Diagnosis
111
Troubleshooting
Check No.07
Refer to P.121
Check No.08
Refer to P.121
Check No.13
Refer to P.123
(R12016)
Caution
NO
YES
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
Monitor the supply voltage,
discharge and suction pressures,
and other factors for a long term.
Possible causes
∗
Instantaneous supply voltage
drop
∗
Compressor overloaded
∗
Short circuit
∗
An output overcurrent signal may result from wrong internal wiring. If the wires have been
disconnected and reconnected and the system is interrupted by an output overcurrent, take the
following procedure.
Check No. 08
Check the discharge pressure.
Check No. 13
Check the power module.
Check No. 07
Check the installation condition.
Check with the inverter checker (
∗
).
Turn off the power and disconnect
the harnesses U, V, and W.
Turn off the power, and reconnect
the harnesses. Turn on the power
again and start operation.
Turn off the power and turn it on
again to start the system. See if the
same error occurs.
Check the supply voltage.
Keep on using as it is.
Check the connectors and
other components.
Fully open the stop valve.
Correct the power supply.
Replace the compressor.
Correct the power supply or
replace the PM1.
(Replace the outdoor unit
PCB.)
Replace the PM1.
(Replace the outdoor unit
PCB.)
Normal?
Error again?
Stop valve fully open?
Voltage as
rated?
Any LED off?
∗
Inverter checker
Part No.: 1225477
Short circuit
or wire breakage
between compressor's coil
phases?
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
SIENBE04-925_A_FRONT.pdf 126
24/02/2011 13:53:57
Содержание RXL25G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents ...
Страница 14: ...Introduction SiENBE04 925_A xii ...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications ...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356 ...