![Daikin RXL25G2V1B Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970025.webp)
SiENBE04-925_A
Printed Circuit Board Connector Wiring Diagram
Printed Circuit Board Connector Wiring Diagram
11
1.2
Outdoor Unit
1.2.1 RXL20G2V1B
Connectors and
Other Parts
PCB (1): Filter PCB
PCB (2): Main PCB
1) S11
Connector for main PCB
2) HL1, HN1, S
Connector for terminal board
3) E1
Terminal for earth
4) E2
Connector for terminal board (earth)
5) HL2, HN2
Connector for main PCB
6) HR1
Connector for reactor
7) FU3
Fuse (20 A, 250 V)
8) V2, V3
Varistor
1) S10
Connector for filter PCB
2) S20
Connector for electronic expansion valve coil
3) S30
Connector for compressor
4) S40
Connector for overload protector
5) S50
Connector for magnetic relay
6) S70
Connector for fan motor
7) S80
Connector for four way valve coil
8) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
9) HL3, HN3
Connector for filter PCB
10) HR2
Connector for reactor
11) FU1, FU2
Fuse (3.15 A, 250 V)
12) LED A
LED for service monitor (green)
13) V1
Varistor
14) J5
Jumper for improvement of defrost performance
∗
Refer to page 270 for detail.
SIENBE04-925_A_FRONT.pdf 25
24/02/2011 13:53:50
Содержание RXL25G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents ...
Страница 14: ...Introduction SiENBE04 925_A xii ...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications ...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356 ...