![Daikin RXL25G2V1B Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970043.webp)
SiENBE04-925_A
Main Functions
Function and Control
29
1.9
2-Area INTELLIGENT EYE Operation
Outline
The following functions can be performed by a motion sensor (INTELLIGENT EYE).
1. Reduction of the capacity when there is nobody in the room in order to save electricity
(energy saving operation)
2. Dividing the room into plural areas and detecting existence of humans in each area.
Moving the airflow direction to the area with no human automatically to avoid direct airflow
on humans.
Detail
1. Detection method of INTELLIGENT EYE
This sensor detects human motion by receiving infrared rays and displays the pulse wave
output.
The microcomputer in the indoor unit carries out a sampling every 20 msec. and if it detects
10 cycles of the wave in one second in total (corresponding to 20 msec.× 10 = 200 msec.),
and when the ON signal continues 3 sec., it judges human is in the room as the motion
signal is ON
2-area INTELLIGENT EYE sensor is divided into 2 areas and detects humans in each area.
Image of 2-area INTELLIGENT EYE
1 sec
sampling (20 msec)
High
Low
ON
OFF
Sensor output
(Human motion)
ON
OFF
(R2821)
(Condition of 10 times or more output)
(Continue 3 sec.)
Detection signal
from the sensor
Human detection
signal
If the sensor detects the outputs 10 times/sec.
or more, it judges humans exist.
If the detection signal (ON) continues 3 sec. or more,
it judges humans exist.
Top view
(R12276)
Indoor unit
Wall
Area A
Area B
· A microcomputer judges human existence by
the sensor signal from each area A and B.
SIENBE04-925_A_FRONT.pdf 43
24/02/2011 13:53:52
Содержание RXL25G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents ...
Страница 14: ...Introduction SiENBE04 925_A xii ...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications ...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356 ...