![Daikin RXL25G2V1B Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/daikin/rxl25g2v1b/rxl25g2v1b_service-manual_501970031.webp)
SiENBE04-925_A
Printed Circuit Board Connector Wiring Diagram
Printed Circuit Board Connector Wiring Diagram
17
1.2.4 RXL35G2V1B
Connectors and
Other Parts
PCB (1): Main PCB
PCB (2): Service Monitor PCB
1) S10
Connector for terminal board (indoor-outdoor transmission)
2) S20
Connector for electronic expansion valve coil
3) S40
Connector for overload protector
4) S51, S101
Connector for service monitor PCB
5) S70
Connector for fan motor
6) S80
Connector for four way valve coil
7) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
8) AC1, AC2
Connector for terminal board (power supply)
9) E1, E2
Connector for earth
10) HR1, HR2
Connector for reactor
11) U, V, W
Connector for compressor
12) FU1
Fuse (30 A, 250 V)
13) FU2, FU3
Fuse (3.15 A, 250 V)
14) V2, V3, V5
V6, V11
Varistor
1) S52, S102
Connector for main PCB
2) LED A
LED for service monitor (green)
3) SW1
Forced operation ON/OFF switch
4) SW4-C
Switch for improvement of defrost performance
∗
Refer to page 270 for detail.
SIENBE04-925_A_FRONT.pdf 31
24/02/2011 13:53:51
Содержание RXL25G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents ...
Страница 14: ...Introduction SiENBE04 925_A xii ...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications ...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356 ...