7-4
Cisco MDS 9000 Fabric Manager Switch Configuration Guide
OL-7753-01
Chapter 7 Configuring High Availability
HA Redundancy States
Table 7-3
Internal States
State
Description
HA standby
This module is the standby supervisor module and
the HA switchover mechanism is enabled.
Active with no standby
This state indicate that a switchover is possible.
Active with HA standby
This module is the active supervisor module and
the switch is ready to be configured. The standby
module is in the HA-standby state.
Shutting down
The switch is being shut down.
HA switchover in progress
The switch is in the process of changing over to
the HA switchover mechanism.
Offline
The switch is intentionally shut down for
debugging purposes.
HA synchronization in progress
The standby supervisor module is in the process of
synchronizing its supervisor modules.
Standby (failed)
The standby supervisor module is not functioning.
Active with failed standby
This module is the active supervisor module and
the second supervisor module is present but is not
functioning.
Other
The switch is in a transient state. If it persists, call
TAC.