Cisco MDS 9000 Fabric Manager Switch Configuration Guide
OL-7753-01
Chapter 23 Configuring FICON
Viewing FICON Director History
Viewing FICON Director History
To view FICON director history, follow these steps:
Step 1
From Device Manager, choose
FICON > VSANs
. You see the FICON VSAN configuration dialog box.
Step 2
Ensure that the VSANs tab is enabled.
Step 3
Click anywhere in the row for the VSAN that you are interested in.
Step 4
Click
Director History
to display a history of FICON-related changes to this switch.
Configuring Code Page
FICON strings are coded in Extended Binary-Coded Decimal Interchange Code (EBCDIC) format.
Refer to your mainframe documentation for details on the code page options. Cisco MDS switches
support
international-5
,
france
,
brazil
,
germany
,
italy
,
japan
,
spain-latinamerica
,
uk
, and
us-canada
(default) EBCDIC format options.
Tip
This is an optional configuration. If you are not sure of the EBCDIC format to be used, we recommend
retaining the
us-canada
(default) option.
Configuring the FC ID Last Byte
FICON requires the last byte of the fabric address to be the same for all allocated FC IDs. By default,
this value is set to 0. You can only change the FC ID last byte when the FICON switch is in the offline
state.
Automatically Saving the Running Configuration
When active equals saved is enabled in a VSAN, any FICON changes to the block, prohibit or port
address name are immediately written to the IPL file (see the
“FICON Configuration Files” section on
page 23-17
).
If active equals saved is enabled in any FICON-enabled VSAN in the fabric, all non-FICON
configuration changes are automatically saved to persistent storage (implicit copy running start) when a
configuration is changed. In this case, the current active configuration across all VSANs is saved to
persistent storage.
The table below displays the results of active equals saved being enabled in at least one FICON VSAN.
Note
If your switch or fabric consists of multiple FICON -enabled VSANs, and one of these VSANs have
active equals saved enabled, changes made to the non-FICON configuration results in all configurations
being saved to the startup configuration.