24-44
Cisco MDS 9000 Fabric Manager Switch Configuration Guide
OL-7753-01
Chapter 24 Configuring IP Storage
Default IP Storage Settings
Default IP Storage Settings
Table 24-1
lists the default settings for Gigabit Ethernet parameters.
Table 24-2
lists the default settings for FCIP parameters.
Table 24-3
lists the default settings for iSCSI parameters.
Table 24-1
Default Gigabit Ethernet Parameters
Parameters
Default
IP MTU frame size
1500 bytes for all Ethernet ports
Table 24-2
Default FCIP Parameters
Parameters
Default
TCP default port for FCIP
3225
minimum-retransmit-time
200 milliseconds.
keepalive-timeout
60 seconds.
max-retransmissions
4 retransmissions.
PMTU discovery
Enabled.
pmtu-enable reset-timeout
3600 seconds.
SACK
Enabled.
max-bandwidth
1G.
min-available-bandwidth
15 Mbps.
round-trip-time
1 ms.
buffer size
0 KB.
Control TCP and data connection
No packets are transmitted.
TCP congestion window monitoring
Enabled
Burst size
10KB.
TCP connection mode
active mode is enabled.
special-frame
Disabled.
FCIP timestamp
Disabled.
acceptable-diff range to accept packets
+ or - 1000 milliseconds.
B port keepalive responses
Disabled
Table 24-3
Default iSCSI Parameters
Parameters
Default
Number of TCP connections
One per iSCSI session.
Fibre Channel targets to iSCSI
Not imported.