3-18
COPYRIGHT © 1999 CANON INC.
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A
CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
Figure 3-A506
Figure 3-A507
Figure 3-A508
[13]
[11]
[10]
[11]
[12]
[13]
[13]
[14]
4) Disconnect the connector [10], and re-
move the two screws [11]; then, detach
the scanning lamp [13] from the electrode
plate (front) [12].
5) Pull out the scanning lamp (w/ the scan-
ning lamp heater) [13] by pulling it to the
front.
6) Remove the scanning lamp heater [14]
from the scanning lamp [13].