CHAPTER 6 IMAGE FORMATION SYSTEM
6-34
COPYRIGHT © 1999 CANON INC.
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Figure 6-315 Sequence of Operations
3.
Correcting the Output upon Detection of Leakage
The separation output is decreased upon detection of leakage.
COPIER > OPTION > BODY > SP-MODE
Set
Low voltage mode
10.5 kvpp
9.8 kvpp
9.8 kvpp
9.2 kvpp
NG
E068 indicated
Main power switch
OFF/ON
Upon detection of leakage cur-
rent, the output is decreased,
and tried again.
COPIER>OPTION>BODY>
SP-MODE
Related Service Mode
0: standard mode. (default; AC output is 10.5 kVpp)
1: low voltage mode (AC output is 9.8 kVpp; select if errors
caused by leakage occur frequently)
Содержание ImageRunner 600
Страница 118: ...4 8 COPYRIGHT 1999 CANON INC CANON imageRUNNER 600 REV 1 JAN 2000 PRINTED IN U S A ...
Страница 577: ...COPYRIGHT 2000 CANON INC CANON imageRUNNER 600 REV 1 JAN 2000 PRINTED IN U S A 13 5 Blank Page ...
Страница 638: ...CHAPTER 13 TROUBLESHOOTING 13 66 COPYRIGHT 1999 CANON INC CANON imageRUNNER 600 REV 1 JAN 2000 PRINTED IN U S A ...