Solution 6000
Installation Manual
Device Programming
10-4
Bosch Security Systems 07/14 BLCC610I
Disarming Allowed
Selecting this option allows the user to turn off (disarm)
the area that the keypad or LAN reader is assigned to
when a valid PIN, token or fingerprint presented. The
user must have access to the area that the keypad or LAN
reader has been assigned to. See MENU 1-6-1 — Reader
Area Assignment.
Single Button Control
This option allows single key arming (All On or Part On)
and single key disarming (from Part On or Part 2 On)
when using the keypad. Refer to programming areas for
respective options set per area.
All User Areas
This option allows the user to turn on or off all areas that
the user has been assigned to at the same time when
they swipe their token or fingerpint. At the keypad, the
user would simply enter their PIN and then press and
hold the [ON], [PART] or [OFF] keys to turn on or off all
areas they belong to.
i
Note
In version 2.15, a fingerprint reader can now be
used to arm or disarm all user areas if required. A
fingerprint user now has the ability to turn all areas
they belong to All On, Part On or Off when they
present their fingerprint at the reader when Option 5
- All User Areas are set in MENU 6-1-2. The following
two tables outline door control with both non
badging and badging operations.
Non Badging
Area Is All On
Present Finger Once
=
Open Door +
Turns Off All User Areas
Area Is Part On
Present Finger Once
=
Open Door +
Turns Off All User Areas
Area Is Off
Present Finger Once
=
Open Door +
Turns On All User Areas
Present Finger and Hold
=
Opens Door +
Turns Part On All User Areas
Table 26: Fingerprint - Non Badging Examples
Badging Allowed
Area Is All On
Present Finger Once
=
Open Door +
Turns Off All User Areas
Area Is Part On
Present Finger Once
=
Open Door +
Turns Off All User Areas
Area Is Off
Present Finger Once
=
Open Door
Present Finger and Hold
=
Opens Door +
Turns On All User Areas
Table 27: Fingerprint - Non Badging Examples
Zero Exit Time
Selecting this option allow the user to turn the area All
On or Part On/Part 2 On from the keypad or LAN reader
with no exit time.
PIN To Change Area
Setting this option will prevent a user from switching
between different areas on the keypad unless they enter
a valid user PIN.
When this option is not set, users will be able to
change the keypad view to all other areas in the system
regardless of whether or not they have access to those
areas.
Home Area Only
Setting this option will force the keypad to display only
it’s assigned home area information. Therefore a user
cannot toggle (or move) the keypad display to show that
of a different area when the system has been partitioned.
Devices > Keypads & Readers >
Home Area
MENU 6-1-3
0 1
00 - No Area
01 - Security System
05 - Area 5 Name
02 - Area 2 Name
06 - Area 6 Name
03 - Area 3 Name
07 - Area 7 Name
04 - Area 4 Name
08 - Area 8 Name
This menu allows you to assign each keypad or LAN reader
to a default home area (Area 1 to 8). Only 1 home area can
be programmed for each keypad or LAN reader.
If a user toggles the keypad display to view a different
area, the keypad will automatically timeout and move
back to the home area if no key is pressed for a period of
60 seconds.
To prevent users from viewing areas which they do
not have access to, you will need to enable the PIN
Содержание SOLUTION 6000
Страница 1: ...Solution 6000 Security System Installation Guide EN Security Systems ...
Страница 42: ...Solution 6000 Installation Manual Programming Overview 4 12 Bosch Security Systems 07 14 BLCC610I ...
Страница 82: ...Solution 6000 Installation Manual Input Programming 7 16 Bosch Security Systems 07 14 BLCC610I ...