Solution 6000
Installation Manual
Device Programming
10-3
Bosch Security Systems 07/14 BLCC610I
1)
Press [MENU] + [6] + [0] + [9] and use the up and
down arrows to highlight the keypad in the list
then press [OK].
L
Keypad 001 Backlight
Press
SAVE
OK to
H
2)
Use the arrow keys to set the required backlight
level. Each time a key is pressed the backlight will
adjust to the new level. When finished press [OK].
K E YPA D & R E A D E R O P T I O N S
Devices > Keypads & Readers >
Name
-
MENU 6-1-0
K e y p a d 1
N a m e
This menu allows you to program the name or location
description of the keypad or LAN reader.
1)
Enter [MENU] + [6] + [1] + [0] and select the keypad
or LAN reader from the list and press [OK].
Name Kp1
Keypad 1 Name
Press
OK to SAVE
2)
Use the arrow and number keys to move and
change text. When the Reader Name is complete,
press [OK]. At any time you can press the [OFF] key
to clear the text from the current cursor position to
the end of the line.
i
Note
See Alpha Text Programming in Section 4 -
Programming Overview for further detail on entering
alpha text.
Devices > Keypads & Readers >
Area Options
MENU 6-1-2
1
All On Arming Allowed
Y
2
Part On Arming Allowed
Y
3
Disarming Allowed
Y
4
Single Button Control
Y
5
All User Areas
N
6
Zero Exit Time
N
7
PIN To Change Area
N
8
Home Area Only
N
1)
Enter [MENU] + [6] + [1] + [2] and select the keypad
or LAN reader from the list then press [OK].
2)
Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
All On Arming Allowed
Part On Arming Allowed
Disarming Allowed
Press
OK ON OFF MENU
3)
Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
All On Arming Allowed
Selecting this option allow the user to turn the area All
On that the keypad or LAN reader is assigned to when
a valid PIN, token or fingerprint is presented. The user
must have access to the area that the keypad or LAN
reader has been assigned to. See MENU 1-6-1 — Reader
Area Assignment.
Part On Arming Allowed
Selecting this option allows the user to turn the area Part
On or Part 2 On that the keypad or LAN reader is assigned
to when a valid PIN, token or fingerprint is presented.
To Turn Area All On Via Token
From the disarmed state, present the token once to turn
the area All On.
To Turn Area Part On Via Token
Present the token twice within 5 seconds to turn the area
Part On.
To Turn Area Part 2 On Via Token
Present the token three times within 5 seconds to turn
the area Part 2 On.
i
Note
The control panel simultaneously supports both All
On and Part On functions for fingerprint readers by
selecting both Option 1 and Option 2 in this menu.
However, this simultaneous support cannot be used
when the fingerprint reader has been programmed
with badging. See below for correct operation.
All On
To turn an area All On, present your finger and remove
when the reader vibrates indicating a successful read.
To turn the area off, present your finger and remove
when the reader vibrates indicating a successful read.
Part On
To turn the area Part On, present your finger and
remove 2 seconds after the reader vibrates indicating
a successful read.
Содержание SOLUTION 6000
Страница 1: ...Solution 6000 Security System Installation Guide EN Security Systems ...
Страница 42: ...Solution 6000 Installation Manual Programming Overview 4 12 Bosch Security Systems 07 14 BLCC610I ...
Страница 82: ...Solution 6000 Installation Manual Input Programming 7 16 Bosch Security Systems 07 14 BLCC610I ...