Solution 6000
Installation Manual
Installing the Hardware
2-5
Bosch Security Systems 07/14 BLCC610I
PA N E L L E D I N D I C ATO R S
The control panel PCB has two LED indicators (Dialler and
Status LED’s) which display the following information.
Condition
Meaning
Off
Offline
On
On Line (Dialling/Answered)
Flashing
Incoming Call
Table 2: Dialler Indicator LED
Condition
Meaning
Off
Error
On
Error
Flash Once Every 2 Seconds
OK
Flash Fast
AC or Battery Trouble
Table 3: Status Indicator LED
i
Note
During factory defaulting the Status and Dialler LED
indicators will flash alternatively for approximately
15 seconds.
A B O U T T H E K E YPA D
The keypad has 20 keys that allow you to input instructions
and navigate the programming menu’s as required. Some
keys have a secondary function which is activated by
pressing and holding them down for two seconds. Each
key is described below.
Key
Description
to
The numeric keys allow you to enter your
user PIN when required.
Use the [MENU] and the numeric keys
to enter commands. The [MENU] key
is also used to go back one level when
navigating through menus or to exit a
programming location without saving
changes.
The [ON] key allows you to turn an area
or output on. To turn all areas on at the
same time when the system has been
partitioned, press and hold the [ON] key
for two seconds.
The [PART] key allows you to turn an
area Part On. This key can also be used
to bypass a zone or multiple zones when
you press and hold for two seconds after
you enter your PIN.
The [OFF] key allows you to turn an area
or output off. To turn all areas off at the
same time when the system had been
partitioned, press and hold the [OFF] key
for two seconds after you enter your PIN.
The [OK] key allows you to save any
changes and exit the command.
Key
Description
The [MAIL] key allows you to read stored
mail. This key can also be used to initiate
a dialler test when you press and hold for
two seconds.
The [
] key allows you to move the
cursor left when programming text or
telephone numbers.
The [
] key allows you to move the
cursor right when programming text or
telephone numbers.
The [
↑
] key allows you to navigate
through menus or to toggle characters
when programming telephone numbers.
The [
] key allows you to navigate
through menus or to toggle characters
when programming telephone numbers.
Pressing The [
] key will display current
trouble conditions when the area that the
keypad is displaying is disarmed.
+
for 2 sec
Press and hold the [
] and [
↑
] keys
together for 2 seconds will initiate a
panic emergency alarm to be triggered.
If programmed, the sirens will sound and
the monitoring station will be notified.
+
for 2 sec
Press and hold the [
] and [
] keys
together for 2 seconds will initiate a
fire emergency alarm to be triggered. If
programmed, the sirens will sound and
the monitoring station will be notified.
+
for 2 sec
Press and hold the [
↑
] and [
] keys
together for 2 seconds will initate a
medical emergency alarm to be triggered.
If programmed, the sirens will sound and
the monitoring station will be notified.
Table 4: Keypad Key Functions
Figure 9: Keypad Emergency Alarm Trigger’s
i
Note
In previous versions, the hold down emergency alarm
functions using the arrow keys failed to operate
when initiated using graphic keypads that have
built-in smart card readers. This included keypad
fire, keypad panic and keypad medical emergency
alarms.
In version 2.14, the hold down emergency functions
using the arrow keys now function correctly.