Solution 6000
Installation Manual
Comms Programming
9-12
Bosch Security Systems 07/14 BLCC610I
i
Note
All areas on the system will be armed regardless of
there condition when using the DTMF quick arm
function. These functions follow both timer groups
and access groups.
Unlike other systems, no additional hardware or modules
are required for DTMF control.
1)
Once the panel answers the incoming call, if either
option 1, 2, 3 or 4 in MENU 5-3-5 is enabled, then
the panel will play a short welcome jingle. You now
have approximately 5 seconds to enter a valid PIN
and log onto the panel.
2)
Enter PIN followed by the [#] key. If the PIN is valid
the system will respond with two short beeps. If the
PIN is invalid then a single long beep will be heard.
3)
If a valid PIN is not entered in time, the panel will
attempt to establish a modem connection as if
connecting to the Solution Link software.
If this happens you will need to hang up for
approximately 60 seconds before trying again.
Once validated, the following commands can be
performed. See the table below. If no keys are pressed
for 20 seconds then the panel will play the exit jingle
before terminating the session and hanging up. Pressing
[#][#] at any time while connected will cause the panel to
terminate the session.
DTMF CONTROL FUNC TIONS
Operation
Command
Tone
Response
Quick Arm
All Areas
[0] + [#]
High,
Medium,
Low
Log In
OK
[PIN] + [#]
Low, High
Error
Incorrect Entry
Long Beep
Turn Area
ON
[1] + [Area N
o
] + [#] + [1]
Low, High
Turn Area
OFF
[1] + [Area N
o
] + [#] + [2]
High, Low
Turn Output
ON
[2] + [Output N
o
] + [#] + [1]
Low, High
Turn Output
OFF
[2] + [Output N
o
] + [#] + [2]
High, Low
End
Session
[#] + [#]
High,
Medium,
Low
Table 25: DTMF Remote Control Functions
DTMF EXAMPLES
Each example below shows the log on step for clarity. In
practise is only necessary to log on once per DTMF control
session.
To turn Area 1 ON enter the following
[2] [5] [8] [0] [#] = Log ON
[1] + [1] + [#] + [1] = Arm Area 1
To turn Output 10 ON enter the following
[2] [5] [8] [0] [#] = Log ON
[2] + [1] [0] + [#] + [1] = Turn Output 10 ON
To turn Output 12 OFF enter the following
[2] [5] [8] [0] [#] = Log ON
[2] + [1] [2] + [#] + [2] = Turn Output 12 OFF
i
Note
If the DTMF Quick Arm option is enabled
then it is possible to remotely arm all
areas without logging onto the panel.
Simply enter [0] + [#] following the welcome jingle.
Make sure that the phone being used to remotely
control the panel is set to transmit DTMF tones
when keys are pressed during the call. This option is
disabled by default on some phones.
Comms > Remote Access >
Voice Access Code
MENU 5-3-6
9 #
This option sets a 2 digit code which is used to access the
panel from any internal phone connected to the same
telco line as the panel. For this option to work, a CM101B
Voice Module must be connected to the panel.
This default number may need to be changed depending
on the country and or telco exchange / PABX system
being used. Make sure that when the code is entered, no
external phone services are selected or activated. If they
are, then change the code to something else.
It is important to realise that this code is only used to start
the connection process. Once a connection is established,
the voice module will ask the user to enter their PIN before
they will be able to control the panel. The Voice Access
Code is shared by all users who need this type of access to
the panel. See the CM101B documention for more details.
1)
Press [MENU] + [5] + [3] + [6]. The keypad will
display the current DTMF options.
Voice Access Code
9#
Press
OK to SAVE
2)
Using the numeric keys enter the new Voice Access
Code then press [OK] to save and exit or press
[MENU] to exit without saving.
Содержание SOLUTION 6000
Страница 1: ...Solution 6000 Security System Installation Guide EN Security Systems ...
Страница 42: ...Solution 6000 Installation Manual Programming Overview 4 12 Bosch Security Systems 07 14 BLCC610I ...
Страница 82: ...Solution 6000 Installation Manual Input Programming 7 16 Bosch Security Systems 07 14 BLCC610I ...