Solution 6000
Installation Manual
Input Programming
7-12
Bosch Security Systems 07/14 BLCC610I
Inputs > RF Zone >
Delete RF Device
MENU 3-3-1
This menu allows you to delete an RF device .
1)
Press [MENU] + [3] + [3] + [1] and use the up and
down arrows to highlight the zone in the list and
press[OK]. The keypad will only list zones that have
an ID programmed. If no zones have an ID number
programmed, the keypad will display:
No Matching List Items
Found!
Press
OK or MENU
Delete Device ID Zn1
Zone 1 Name
007407097
Press OK or MENU
2)
Press [OK] to DELETE the RF device and exit or press
[MENU] to exit without deleting.
Inputs > RF Zone >
Test RF Device
MENU 3-3-2
This menu allows you to test just how good the current
position is for an RF device. Enter the command and you
will be presented with a list of RF zones in the current area
that are available for test. Use the arrow keys to highlight
the zone to test and press OK. At any time press menu to
exit.
1)
Press [MENU] + [3] + [3] + [2] and use the up and
down arrows to highlight the zone you want to test
in the list and press[OK]. Alternatively, you can
enter the zone number directly and press [OK]. The
system will only list RF zones in the current area.
Zn2 Zone 2 Name
W a i t i n g for Trigger!
Press OK or MENU
2)
Once a signal is received the following information
will be displayed.
Zn2 Zone 2 Name
Transmissions = 001
Signal = Good
Press OK or MENU
Signal can = Good, Average or Relocate
Every time you send a transmission, the number of
transmissions will increment and the average of the signals
with be displayed. Be sure to send a few transmissions to
establish a more accurate signal measurement.
G LO B A L I N P U T O P T I O N S
Inputs > Global Input Options >
EOL Value
MENU 3-4-0
(*** System Wide Parameter ***)
0
5
00 - No EOL
08 - 6k8 Ohm
01 - 1k0 Ohm
09 - 8k1 Ohm
02 - 1k5 Ohm
10 - 10k Ohm
03 - 2k2 Ohm
11 - 6K8 Alarm + 2k2 Tamp
04 - 2k7 Ohm
12 - 10k Alarm + 10k Tamp
05 - 3k3 Ohm
13 - 22k Ohm
06 - 4k7 Ohm
14 - 3k3 Alarm + 6k8 Tamp
07 - 5k6 Ohm
15 - Split EOL 3k3 //6k8
This menu programs the End Of Line resistor (EOL) value
that is global for all hard-wired zones including zones on
the Zone Expander Module. Only one EOL Value can be
programmed.
Setting the EOL Value to type 0 to 14 will configure the
control panel as 8 hardwired zones. Additional zones
via optional zone expander boards will start on zone 9.
Setting the EOL as type 15 will configure the control panel
as 16 hardware zones with zones 17 upwards via optional
zone expander boards.
1)
Press [MENU] + [3] + [4] + [0]. The keypad will
display the current EOL value (Default = 5).
EOL Value
05 - 3k3 Ohm
Press
0-9 OK to SAVE
2)
Use the up and down arrows to select the EOL
Value you want to use then press [OK] to save and
exit or press [MENU] to exit without saving.
Inputs > Global Input Options >
Keyswitch Options
MENU 3-4-1
(*** System Wide Parameter ***)
0 0
00 - Latching All On/Off
05 - Pulse All On/Off
01 - Latching All On
06 - Pulse All On
02 - Latch Part On/Off
07 - Pulse Part
On/Off
03 - Latching Part On
08 - Pulse Part On
04 - Latching Off
09 - Pulse Part Off
This menu programs the properties for any zone in the
system programmed as a keyswitch zone. Only one
option can be selected for the entire system which means
that all keyswitches fitted will behave the same way.
The system can send Open and Close reports based on the
keyswitch operation with the zone number representing
the user number in the report.