Solution 6000
Installation Manual
Device Programming
10-12
Bosch Security Systems 07/14 BLCC610I
i
Note
In previous versions, checking the GSM module status
using MENU 6-0-0 via Device Status or MENU 6-5-
0 via GSM/GPRS Status, the keypad would display
the signal strength in dBm as shown in the example
below:
GSM/GPRS 2G Module Gi1
Signal Strength -83dBm
Press
OK or MENU
In version 2.14, when checking the GSM module status,
the signal strength indication has changed to signal level
with a range of 0 to 5 where 0 = no signal level, 1 = low
signal level and 5 = highest signal level as shown in the
example below:
GSM/GPRS 2G Module Gi1
Signal Level (0-5) = 2
Press
OK or MENU
Devices > GSM/GPRS Module >
GSM/GPRS Options
MENU 6-5-1
1
Auto Forward SMS
N
2
Forward SMS To Mail
Y
3
Reserved
N
4
Reserved
N
5
Reserved
N
6
Reserved
N
7
Reserved
N
8
Reserved
N
This menu option allows you to configure various options
and functions for GSM or GPRS devices connected to the
system.
1)
Press [MENU] + [6] + [5] + [1]. The keypad will
display the current RF Device Options.
Auto Forward SMS
Forward SMS To Mail
Reserved
Press
OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Auto Forward SMS
Any SMS received by the GSM module will be
automatically forwarded to the mobile telephone
number programmed in MENU 6-5-7.
Forward SMS To Mail
Any SMS received by the GSM module will be
automatically forwarded to the keypad (brings up
Main icon). SMs commands will be filtered (eg. ,PIN.,
AREA1,ON).
Devices > GSM/GPRS Module >
CLI Trigger Table 1
-
MENU 6-5-5-0
Phone 1
1
Digits
16
Phone 2
1
Digits
16
Phone 3
1
Digits
16
Phone 4
1
Digits
16
Phone 5
1
Digits
16
Phone 6
1
Digits
16
Phone 7
1
Digits
16
Phone 8
1
Digits
16
Phone 9
1
Digits
16
Phone 10
1
Digits
16
GSM MODULE REQUIRED)
The CLI trigger table allows
you to program up to 10 telphone numbers that the
control panel will automatically identify when you call
the control panel to operate an output - see Output Event
type 71. Program the output event assignment as 1 so
that the output follows CLI trigger table 1.
1)
Enter [MENU] + [6] + [5] + [5] + [0]. The keypad will
display the following:
Phone 1=
Phone 2=
Phone 3=
Press
OK or MENU
2)
Highlight the telephone number that you want to
program for CLI trigger, then press [OK] to select.