Solution 6000
Installation Manual
Access Programming
5-2
Bosch Security Systems 07/14 BLCC610I
Example:
Prox reader operating door and arm/disarm Area 1.
1)
Assign proximity reader 9 to a door assignment 1 -
16, say 4.
2)
Set an output event type = door and index = 4.
3)
Assign user to door 4, a user can belong to multiple
doors.
4)
Assign reader to area 1, enable arming/disarming
and badging options.
5)
Present token to disarm, present token to release
door, present token 3 times to arm Area 1.
U S E R D E FAU LT TA B L E
Parameter
User 1
User 2 - 255
Add PIN
2580
Name
User 1
User 2 - 255
Area Assignment
1
1
User Options
Master User
Y
Reserved
Arm Only
Can Bypass
Y
Y
Auto Bypass Allowed
Y
Y
Always Report Op/Cl
Y
Y
Reserved
Log Credential
TimeZone Access
Door Assignment
Table 19: User Default Programming Options
U S E R P I N S
At factory default, each PIN is set to 4 digits in length.
The default PIN for User 1 (master user) is 2580. Only the
installer can change the PIN length - see MENU 1-5-0 —
PIN Length.
Access > Commands >
Erase User
-
MENU 1-0-0
This menu allows the installer or master user, to erase
another user. When a user is erased, it will return back to
factory default all information relating to the following:
PIN
Token ID
RF Keyfob ID
Fingerprint ID
Name
TimeZone Access
Door Assignment
Area Assignment
1)
Enter [MENU] + [1] + [0] + [0].
2)
Use the arrow keys to highlight the user to be
erased then press [OK].
Ur1 John Smith
Ur2 Debbie Smith
Ur3 User 3 Name
Press
OK or MENU
3)
Verify the user name to be erased and press [OK].
To abort press [MENU].
To erase Ur1
John Smith
press OK.
Press OK or MENU