Solution 6000
Installation Manual
Comms Programming
9-15
Bosch Security Systems 07/14 BLCC610I
Comms > Reporting >
Test Route
MENU 5-4-2
00 - Log Events Only
0
1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
(*** System Wide Parameter ***)
This menu programs which destination will be used to
send both manual and automatic test reports.
1)
Press [MENU] + [5] + [4] + [2]. The keypad will
display the current Test Route.
Test Route
01 - Dest 1 + Log
Press
0-9 OK to SAVE
2)
Use the up and down arrow keys to select the Test
Route required then Press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > Reporting >
System Route
MENU 5-4-3
00 - Log Events Only
0
1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
(*** System Wide Parameter ***)
This menu sets the report destination that will be used to
send all system event reports.
1)
Press [MENU] + [5] + [4] + [3]. The keypad will
display the current Status Report route.
System Route
01 - Dest 1 + Log
Press
0-9 OK to SAVE
2)
Use the up and down arrow keys to select the Test
Route required then Press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > Reporting >
Emergency Route
MENU 5-4-4
00 - Log Events Only
0
1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
(*** System Wide Parameter ***)
This menu programs the destination that all Keypad
emergency alarms are reported.
1)
Press [MENU] + [5] + [4] + [4]. The keypad will
display the current Emergency Route.
Emergency Route
01 - Dest 1 + Log
Press
0-9 OK to SAVE
2)
Use the up and down arrow keys to select the
Keypad Emergency route required then Press [OK]
to save and exit or press [MENU] to exit without
saving.
Comms > Reporting >
Swinger Dialler
MENU 5-4-5
(*** System Wide Parameter ***)
0 6
Swinger Dialler can be used to prevent a faulty or run-
a-way PIR from continually re-triggering the zone and
reporting to the base station.
The Swinger Dialler count sets the maximum number of
times an individual zone can trigger an alarm during the
current arming cycle before it is locked out.
If this option is not programmed, the panel will continue
to report the alarm signal until the system or area is
disarmed.
Only zones that have been programmed for Lockout
Dialler in MENU 3-1-7 — Report Options will follow the
Swinger Dialler count.
1)
Press [MENU] + [5] + [4] + [5]. The keypad will
display the current Swinger Dialler count.
Swinger Dialler
6
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the new Swinger
Dialler count then press [OK] to save and exit or
press [MENU] to exit without saving. Valid entries
are 0 - 15 / 0 = disabled.