Solution 6000
Installation Manual
Output Programming
8-9
Bosch Security Systems 07/14 BLCC610I
Outputs > Properties >
Event Assignment
MENU 4-1-2
0 0 0
(A) =
Area Assignment
Assign to Area 1 to 8 (0 = Any Area)
(P) = Control Panel
(O) =
Output Assignment
Assign to Output 1 to 40 (0 = Any Output)
(Z) =
Zone Assignment
Assign to Zone 1 to 144 (0 = Any Zone)
(U) =
User Assignment
Assign to User 1 to 255 (0 = Any User)
(TZ) =
TimeZone Assignment
Assign to TimeZone 1 to 16 (0 = Any TimeZone)
(Dr) =
Door Assignment
(Assign to Door 1 to 16 (0 = Any Door)
(K) =
Keypad Assignment
Assign to Keypad/LAN Reader 1 to 16 (0 = Any Keypad/
LAN Reader)
(T) =
CLI Table Assignment
Assign to CLI Table 1 to 2 (0 = Any CLI Table)
(D) =
Reporting Destination Assignment
Assign to Destination 1 or 2 (0 = Any Destination)
(CLI)
CLI Trigger Table
Assign to CLI Trigger Table 1 or 2 (0 = Both Tables)
(Mac)
Macro
Assign to Macro
This menu allows you to assign the output event to an
individual area, user, zone or door etc. Programming a
zero will assign the output event to follow any area, user,
zone or door etc depending on the event type.
Refer to Output Event Type Table for a complete listing of
available options.
1)
Press [MENU] + [4] + [1] + [2] and select the output
you want to operate from the list then press [OK].
Alternatively, you can directly enter the output
number then press [OK]. The keypad will display
the current Event Assignment.
Event Assignment Op1
00 - All Areas
Press
0-9 OK to SAVE
2)
Use the up and down arrow keys to select the
Output Event Assignment then press [OK] to save
and exit or press [MENU] to exit without saving.
Outputs > Properties >
Output Polarity
MENU 4-1-3
0 0
00 - Open To Low
08 - Low To Open + Pre
01 - Open To Low + Pre
09 - Low Latching Open
02 - Open Latching Low
10 - Low Pulsing Open
03 - Open Pulsing Low
11 - Low 1 Shot Open
04 - Open 1 Shot Low
12 - 1 Shot Open+Retrigger
05 - 1 Shot Low+Retrigger
13 - 1 Shot Open + Reset
06 - 1 Shot Low + Reset
14 - Speaker Output
07 - Low To Open
15 - Toggle
The output polarity programs how the output will operate.
Only one option (0 – 15) can be programmed per output.
See the Output Polarity description for more detailled
information.
1)
Press [MENU] + [4] + [1] + [3] and use the up and
down arrows to highlight the output in the list and
press [OK]. The keypad will display the current
output polarity.
Output Polarity Op1
14 - Speaker Output
Press
0-9 OK to SAVE
2)
Use the up and down arrow keys to select the
Output Polarity required then press [OK] to save
and exit or press [MENU] to exit without saving.
Open To Low
Output is normally open circuit and switches to GND
when the event occurs. The output will reset when the
output event restores. Time parameters do not apply to
this polarity type.
Open To Low + Pre
Output is normally open circuit and switches to GND
when the event occurs provided the time parameter has
expired. The output will reset when the output event
restores. Time parameters will only set the Pre Delay
when this polarity is selected.
Open Latching Low
Output is normally open circuit and will switch to zero
volts when the event occurs. The output can only be
reset manually using the Output Command Menu.
Open Pulsing Low
Output is normally open circuit and will pulse LOW when
the event occurs. The output will reset when the output
event restores. Use the Time Parameter to set the pulse
duration.