Solution 6000
Installation Manual
Input Programming
7-15
Bosch Security Systems 07/14 BLCC610I
To test zone Zn1
open then close
Zone 1 Name
Press OK or MENU
3)
Open and close the zone that needs to be tested.
When the test has been completed the keypad will
display:
Zn1 Zone 1 Name
Test Successful
Press OK or MENU
4)
Press [OK] or [MENU] to exit.
Inputs > Input Testing >
Sensor Watch Time
MENU 3-9-2
(*** System Wide Parameter ***)
0 3 0
Days
This menu programs the Sensor Watch Time interval.
Zones programmed for Sensor Watch are required to seal
and unseal at least once within the Sensor Watch Time
period or a trouble message will be displayed on the
keypad and a Zone Trouble report sent.
Valid entries are 001 -255 Days and 000 = Sensor Watch
Disabled
5)
Press [MENU] + [3] + [9] + [2]. The keypad will
display the current sensor watch time (Default = 30
days).
Sensor Watch Time
030 Days
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the new Sensor
Watch time in days then press [OK] to save and exit
or press [MENU] to exit without saving.
i
Note
Sensor Watch monitoring is only active when the
area is in the disarmed state. 24 hour zone types
cannot be monitored using the Sensor Watch feature.