Solution 6000
Installation Manual
Output Programming
8-16
Bosch Security Systems 07/14 BLCC610I
O U T P U T A S S I G N M E N TS
Output Assignment
Module
Number
Address Setting
Output Number
SW1 SW2 SW3 SW4 SW5
Control Panel
1 to 5
Virtual Outputs
6 to 8
1 =
OFF OFF OFF OFF OFF
9 to 12
2 =
ON OFF OFF OFF OFF
13 to 16
3 =
OFF ON OFF OFF OFF
17 to 20
4 =
ON ON OFF OFF OFF
21 to 24
5 =
OFF OFF ON OFF OFF
25 to 28
6 =
ON OFF ON OFF OFF
29 to 32
7 =
OFF ON ON OFF OFF
33 to 36
8 =
ON ON ON OFF OFF
37 to 40
Table 24: Address Configuration and Output Assignments
O U T P U T D E FAU LT TA B L E
The table below list the default values for all Output parameters in the Solution 6000. Outputs 1 to 4 are High current
digital outputs and Output 5 is the onboard relay output. Outputs 9 to 40 are only available if the optional Output Relay
Expander Boards (CM710B) are fitted. Options marked N/A = Not Applicable.
Programming Option
Output 1
Output 2
Output 3
Output 4
Output 5
Output 9 - 40
Output Name
External
Siren
Strobe
Light
Smoke Sensor
PWR
Internal
Siren
On Board
Relay
Output x Name
Event Type
36
(External
Siren)
48
(Strobe)
49
(Smoke Sensor
GND)
37
(Internal
Siren)
54
(Keyfob
Function 2)
00
(Not Used)
Event Assignment
0
0
0
0
0
0
Output Polarity
14
Speaker
Output
6
1 Shot Low +
Reset
11
Low 1 Shot
Open
6
1 Shot Low +
Reset
4
Open 1 Shot
Low
0
Open
To Low
Time Parameter
N° Of Hours
000
008
000
000
000
000
N° Of Minutes
005
000
000
005
000
000
N° Of Seconds
000
000
010
000
002
000
N° Of 1/10 Seconds
000
000
000
000
000
000
Output Options
Off On Low Battery
Y
Y
N
Y
N
N
Guest Control
N
N
N
N
N
N
Reserved
N
N
N
N
N
N
Monitor Overload
Y
Y
Y
Y
N
N
Monitor Device Fail
Y
Y
N
Y
N
N
Alarm On Device Fail
N
N
N
N
N
N
Block If All On
N
N
N
N
N
N
Show Status On Keypad
N
N
N
N
N
N
Table 28: Output Default Table
Содержание SOLUTION 6000
Страница 1: ...Solution 6000 Security System Installation Guide EN Security Systems ...
Страница 42: ...Solution 6000 Installation Manual Programming Overview 4 12 Bosch Security Systems 07 14 BLCC610I ...
Страница 82: ...Solution 6000 Installation Manual Input Programming 7 16 Bosch Security Systems 07 14 BLCC610I ...