Solution 6000
Installation Manual
Input Programming
7-13
Bosch Security Systems 07/14 BLCC610I
1)
Press [MENU] + [3] + [4] + [1]. The keypad will
display the current keyswitch options (Default = 0
Disabled).
Keyswitch Options
00 - Latching All On/Off
Press
0-9 OK to SAVE
2)
Use the up and down arrows to select the required
keyswitch option then press [OK] to save and exit
or press [MENU] to exit without saving.
Inputs > Global Input Options >
Input Options
MENU 3-4-2
1
Tamper On Short
N
2
Reserved
N
3
Response Time 500msec
N
4
Reserved
N
5
Keyswitch Open Close
Y
6
Alarm On Tamper
N
7
Reserved
N
8
Reserved
N
(*** System Wide Parameter ***)
This menu programs the various global input options
which will effect all zones on the system.
1)
Press [MENU] + [3] + [4] + [2]. The keypad will
display the current input options.
Tamper On Short
Reserved
Response Time 500msec
Press
OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Tamper On Short
Setting this option will cause any Zone which become
shorted to report a tamper alarm condition for the zone.
Response Time 500msec
Setting this option will increase the response time for all
zones to 500ms.
Keyswitch Open Close
This feature allows you to select whether or not a zone
programmed as a Keyswitch Zone, will send opening and
closing reports. The default is set to Off.
Alarm On Tamper
This option allows tamper circuits on RF sensors and
hardwire zones to sound an alarm when faulted when
their corresponding area is turned off (disarmed).
Inputs > PGM Input >
Input Type
MENU 3-5-0
0 0
00 - Disabled
01 - Latching On/Off
04 - Bosch Serial Rcvr
02 - Pulse On/Off
05 - Crow Serial Rcvr (TBA)
03 - Simple RF On/Off
This menu option is used to configure the systems
programmable input terminal. Various devices can be
connected including keyswitches of radio controlled relays
etc. When RF zones are required you need to connect the
RF receiver to this input
Connect keyswitch between Input terminal and GND.
See Wiring Diagrams in Section 3 for various connection
diagrams.
1)
Press [MENU] + [3] + [5] + [0]. The keypad will
display the current input type (Default = 0
Disabled).
Input Type
00 - Disabled
Press
0-9 OK to SAVE
2)
Use the up and down arrows to select the required
Input Device Type then press [OK] to save and exit
or press [MENU] to exit without saving.
i
Note
The Latching and Momentary On/Off modes
are active low, and when triggered, they will
automatically force arm the area.