Solution 6000
Installation Manual
Comms Programming
9-25
Bosch Security Systems 07/14 BLCC610I
4)
Press [OK] or [MENU] to exit.
Comms > Comms Test >
Test Report Time
MENU 5-9-1
Test Time
0 2
:
0 0
H H
:
M M
This menu programs the time of the day that the panel
will send the automatic Test Report to the base station
receiver. Automatic test reports are used to verify the
panels ability to report events via the telephone line on
an ongoing basis.
1)
Press [MENU] + [5] + [9] + [1]. The keypad will
display the current Test Report Time.
Test Report Time
02:00am
Press
OK to SAVE
2)
Use the left, right, up and down arrow keys to
select the Test Report time required then Press [OK]
to save and exit or press [MENU] to exit without
saving.
i
Note
Scroll through the hours using the up and down
arrow keys to change the time from am to pm.
Comms > Comms Test >
Test Report Period
MENU 5-9-2
(*** System Wide Parameter ***)
0 1
00 - No Test Report
08 - Reserved
01 - Every Day
09 - Reserved
02 - Every Week
10 - Reserved
03 - Every Month
11 - Reserved
04 - Every 2 Days
12 - Reserved
05 - Every 3 Days
13 - Reserved
06 - Every 4 Days
14 - Every Hour
07 - Every 5 Days
15 - Every 12 Hours
This menu programs how often the control panel will
send a test report. Only one option can be programmed.
1)
Press [MENU] + [5] + [9] + [2]. The keypad will
display the current Test Report Period.
Test Report Period
01 - Every Day
Press
0-9 OK to SAVE
2)
Use the up and down arrow keys to select the Test
Report Period then Press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > Comms Test >
Test Report Options
MENU 5-9-3
1
Test If No Other Rpt
N
2
Test On Siren Reset
Y
3
Reserved
N
4
Reserved
N
5
Reserved
N
6
Reserved
N
7
Reserved
N
8
Reserved
N
1)
Press [MENU] + [5] + [9] + [3]. The keypad will
display the current Test Report Options.
Test If No Other Rpt
Test On Siren Reset
Reserved
Press
OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Test If No Other Rpt
Setting this option will cause the system to only send its
automatic Test report if no other area report has been
sent within the test report time period as programmed in
MENU 5-9-2.
Test On Siren Reset
Setting this option will delay the Automatic Test Report if
the sirens are running when the test report time expires.
This effectively keeps the telco line free to make any
further alarm reports which may be triggered while the
sirens are running. The panel will send the cued Test
Report as soon as the siren run-time has expired.
i
Note
In previous versions, the control panel would send
a ‘Test Report - Auto’ SMS message whenever the
control panel returned to normal state after a trouble
event had been cleared.
In version 2.14, when using SMS format or GSM
SMS format, the control panel no longer sends
the ‘Test Report - Auto’ message when the control
panel returns to normal after trouble condition.
Содержание SOLUTION 6000
Страница 1: ...Solution 6000 Security System Installation Guide EN Security Systems ...
Страница 42: ...Solution 6000 Installation Manual Programming Overview 4 12 Bosch Security Systems 07 14 BLCC610I ...
Страница 82: ...Solution 6000 Installation Manual Input Programming 7 16 Bosch Security Systems 07 14 BLCC610I ...