Solution 6000
Installation Manual
Device Programming
10-16
Bosch Security Systems 07/14 BLCC610I
Devices > Ethernet Module >
Default Gateway
MENU 6-6-2
1
Digits
12
0 0 0
0 0 0
0 0 0
0 0 0
The can be found by running IPCONFIG on a PC connected
to the clients network.
1)
Press [MENU] + [6] + [6] + [2]. The keypad will
display the current gateway number.
Default Gateway
000000000000
Press 0-9 OK to SAVE
2)
Use the numeric keys [0] to [9] + [
←
] and [
→
] keys
to program the 12 digit gateway number, then
press [OK] to save and exit or press [MENU] to exit
without saving.
Devices > Ethernet Module >
Module MAC Address
MENU 6-6-3
0 0
0 0
0 0
0 0
0 0
0 0
This is the hardware machine address of the module and
can be found on the bar-coded sticker.
1)
Press [MENU] + [6] + [6] + [3]. The keypad will
display the current MAC address.
Module MAC Address
000000000000
Press
OK to SAVE
2)
Use the numeric keys [0] to [9] + [
←
] and [
→
] keys
to program the MAC address, then press [OK] to
save and exit or press [MENU] to exit without
saving. This is the hardware machine address of the
module and can be found on the bar-coded sticker.
Devices > Ethernet Module >
Ethernet Options
MENU 6-6-9
1
Display Faults
Y
2
Report Cable Lost
Y
3
Report IP Conflict
Y
4
Report Poll Fail
Y
5
Reserved
N
6
Reserved
N
7
Reserved
N
8
Reserved
N
This menu option allows you to configure the various RF
receiver functions. Only one RF reciever can be fitted per
panel.
1)
Enter your Installer PIN + [MENU].
2)
Enter [6] + [6] + [9] + [OK].
The keypad will display the current options which are
selected or enabled.
Display Faults
Report Cable Lost
Report IP Conflict
Press
OK ON OFF MENU
3)
Use the numeric keys [1] to [8] to turn on and off
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
4)
When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Display Faults
This option allows the keypad to display a trouble
condition if the control panel detects when the ethernet
module is missing, the module IP is changed, there is no
connection, there is an IP lockout or there is an IP conflict.
Report Cable Lost
This option allows the control panel to report when it
detects that the LAN cable is missing via the dialler.
Report IP Conflict
This option allows the control panel to report an IP
conflict via the dialler when it detects two computers
on the LAN or internet have been assigned the same IP
address.
Report Poll Fail
This option allows the control panel to report via the
dialler when the ethernet module fails to send a poll to
the base station.
» » E N D O F S E C T I O N « «