Solution 6000
Installation Manual
Area Programming
6-7
Bosch Security Systems 07/14 BLCC610I
Keyswitch On/Off
When selected, the panel will activate the strobe
output for six seconds when a user turns the area on
via a keyswitch zone or the programmable input. This
provides silent feedback to the user that the signal has
been received when turning the area on or off.
24Hr Alarm
When selected, the panel will activate the strobe output
when a zone programmed as 24-hour (audible or silent)
has registered an alarm. Zones programmed as 24-Hour
Hold-Up are not included.
Areas > Area Properties >
Part Mode 1 Name
-
MENU 2-1-6
P a r t
1 A r e a
1
N a m e
This menu allows you to program the name for each area
when turning the area Part On or Part 2 On. Each area
name can be programmed with up to 20 characters. At
factory default, only Area 1 is used. The control panel can
have a maximum of 8 independent areas programmed.
1)
Enter [MENU] + [2] + [1] + [6] and select the area
from the list and press [OK].
Part Mode 1 Name A1
Part 1 Area 1 Name
Press
OK to SAVE
2)
Use the arrow and number keys to move and
change text. When the area name is complete,
press [OK]. At any time you can press the [OFF] key
to clear the text from the current cursor position to
the end of the line.
i
Note
See Alpha Text section in Section 4 - Programming
Overview for further detail on entering alpha text.
Areas > Area Properties >
Part Mode 2 Name
-
MENU 2-1-7
P a r t
2 A r e a
1
N a m e
This menu allows you to program the name for each area
when turning the area Part On or Part 2 On. Each area
name can be programmed with up to 20 characters. At
factory default, only Area 1 is used. The control panel can
have a maximum of 8 independent areas programmed.
1)
Enter [MENU] + [2] + [1] + [6] and select the area
from the list and press [OK].
Part Mode 2 Name A1
Part 2 Area 1 Name
Press
OK to SAVE
2)
Use the arrow and number keys to move and
change text. When the area name is complete,
press [OK]. At any time you can press the [OFF] key
to clear the text from the current cursor position to
the end of the line.
i
Note
See Alpha Text section in Section 4 - Programming
Overview for further detail on entering alpha text.
Areas > Area Properties >
Auto Arming
-
MENU 2-1-8
0 0
00 - Disabled
01 - 24 Hour TimeZone
09 - TimeZone 9 Name
02 - TimeZone 2 Name
10 - TimeZone 10 Name
03 - TimeZone 3 Name
11 - TimeZone 11 Name
04 - TimeZone 4 Name
12 - TimeZone 12 Name
05 - TimeZone 5 Name
13 - TimeZone 13 Name
06 - TimeZone 6 Name
14 - TimeZone 14 Name
07 - TimeZone 7 Name
15 - TimeZone 15 Name
08 - TimeZone 8 Name
16 - TimeZone 16 Name
This menu allows you to assign which time zone the area
will follow to automatically turn the area All On and/or
off (disarm). Only one time zone can be assigned to each
area.
1)
Enter [MENU] + [2] + [1] + [8] and select the area
from the list and press [OK].
Auto Arming A1
00 - Disabled
Press
0-9 OK to SAVE
2)
Use the arrow and number keys to select the time
zone that you want the area to follow, then press
[OK] to save and exit.