Solution 6000
Installation Manual
Programming Overview
4-6
Bosch Security Systems 07/14 BLCC610I
DT M F CO N T R O L F U N C T I O N S
Firmware includes comprehensive DTMF control of
individual areas and outputs with full user PIN and TIMER
GROUP access verification.
Unlike other systems, no additional hardware or modules
are required for DTMF control. To configure the desired
functions see MENU 5-3-5 DTMF Options.
How to Use DTMF Control
1)
Once the panel answers the incoming call, if either
option 1, 2, 3 or 4 in MENU 5-3-5 is enabled, then
the panel will play a short welcome jingle. You now
have approximately 5 seconds to enter a valid PIN
and log onto the panel.
2)
Enter PIN followed by the [#] key. If the PIN is valid
the system will respond with two short beeps. If the
PIN is invalid then a single long beep will be heard.
If a valid PIN is not entered in time, the panel will attempt
to establish a modem connection as if connecting to the
Solution Link software.
If this happens you will need to hang up for approximately
60 seconds before trying again.
3)
Once validated, the following commands can be
performed. See the table below. If no keys are
pressed for 20 seconds then the panel will play the
exit jingle before terminating the session and
hanging up. Pressing [#][#] at any time while
connected will cause the panel to terminate the
session.
DTMF CONTROL FUNC TIONS
Operation
Command
Tone
Response
Quick Arm
All Areas
[0] + [#]
High,
Medium,
Low
Log In
OK
[PIN] + [#]
Low, High
Error
Incorrect Entry
Long Beep
Turn Area
ON
[1] + [Area N
o
] + [#] + [1]
Low, High
Turn Area
OFF
[1] + [Area N
o
] + [#] + [2] + [#]
High, Low
Turn Output
ON
[2] + [Output N
o
] + [#] + [1] + [#]
Low, High
Turn Output
OFF
[2] + [Output N
o
] + [#] + [2] + [#]
High, Low
End
Session
[#] + [#]
High,
Medium,
Low
Table 17: DTMF Remote Control Functions
DTMF EXAMPLES
Each example below shows the log on step for clarity. In
practise is only necessary to log on once per DTMF control
session.
To turn Area 1 ON enter the following
[2] [5] [8] [0] [#]
= Log ON
[1] + [1] + [#] + [1]
= Arm Area 1
To turn Output 10 ON enter the following
[2] [5] [8] [0] [#]
= Log ON
[2] + [1] [0] + [#] + [1]
= Turn Output 10 ON
To turn Output 12 OFF enter the following
[2] [5] [8] [0] [#]
= Log ON
[2] + [1] [2] + [#] + [2]
= Turn Output 12 OFF
i
Note
If the DTMF Quick Arm option is enabled
then it is possible to remotely arm all
areas without logging onto the panel.
Simply enter [0] + [#] following the welcome jingle.
Make sure that the phone being used to remotely
control the panel is set to transmit DTMF tones
when keys are pressed during the call. This option is
disabled by default on some phones.
Содержание SOLUTION 6000
Страница 1: ...Solution 6000 Security System Installation Guide EN Security Systems ...
Страница 42: ...Solution 6000 Installation Manual Programming Overview 4 12 Bosch Security Systems 07 14 BLCC610I ...
Страница 82: ...Solution 6000 Installation Manual Input Programming 7 16 Bosch Security Systems 07 14 BLCC610I ...