Solution 6000
Installation Manual
Comms Programming
9-7
Bosch Security Systems 07/14 BLCC610I
Comms > Properties >
Dialler Options
MENU 5-2-1
1
Dialler Enabled
Y
2
Pulse Dialling
N
3
Dial Tone Detect
Y
4
Busy Tone Detect
N
5
Mirror Report To Web
Y
6
Extend H/S To 1min
N
7
Reserved
N
8
Abort Failed Reports
Y
1)
Press [MENU] + [5] + [2] + [1]. The keypad will
display the current Dialler Options.
Dialler Enabled
Pulse Dialling
Dial Tone Detect
Press
OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Dialler Enabled
This option enables the dialler reporting function. When
disabled, all dialler reporting will stop.
Pulse Dialling
This option will configure the panel to use pulse or
decadic dialling rather than tone or DTMF dialling. DTMF
dialling should always be used unless the telephone
network you are communicating on does not support it.
Dial Tone Detect
This option configures the panel to start dialling as soon
as it detects dial tone on the line. This can speed up the
dialing process by up to 3 seconds. If no tone is detected
the panel will blind dial after 4 seconds.
If this option is disabled the panel will blind dial.
Busy Tone Detect
This option configures the panel to detect busy tone. If a
busy tone is detected during the dialling sequence, the
panel will immediatly hang up and move on to the next
number in the sequence in an attempt to get the report
through as quickly as possible.
If this option is disabled, the panel will wait for a period
of 30 seconds before dialling the next telephone number
in the sequence. The 30 second timer starts when the
first digit of the first telephone number is dialled.
Mirror Report WEB
Reserved.
Extend H/S To 1min
This option sets the panel to wait for up to 60 seconds
to receive a valid handshake signal from the base station
receiver. The handshake tone indicates to the panel
that it has reached the security company’s base station
receiver and can now send it’s pending reports.
If this option is disabled the handshake wait time will
default to 30 seconds.
Abort Failled Reports
Setting this option will cause a failled report to be
flagged in the log and no further reports will be made for
that event.
i
Note
A report will be failled if the number of programmed
dial attempts has been reached .
Comms > Properties >
Phone Line Options
MENU 5-2-2
1
Display Line Fail
Y
2
Report Line Fail
Y
3
Alarm L/Fail If On
Y
4
Alarm L/Fail If Off
N
5
Reserved
N
6
Digital Line
N
7
Low Voltage
N
8
Display On Line
N
1)
Press [MENU] + [5] + [2] + [2]. The keypad will
display the current Phone Line Options.
Display Line Fail
Report Line Fail
Alarm L/Fail If On
Press
OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Display Line Fail
This option sets the panel to display a trouble signal on
the keypad display when the panel detects a teleco line
fail condition.
Report Line Fail
This option sets the panel to send a line fail report
when it detects a telco line fail condition. If configured,
Содержание SOLUTION 6000
Страница 1: ...Solution 6000 Security System Installation Guide EN Security Systems ...
Страница 42: ...Solution 6000 Installation Manual Programming Overview 4 12 Bosch Security Systems 07 14 BLCC610I ...
Страница 82: ...Solution 6000 Installation Manual Input Programming 7 16 Bosch Security Systems 07 14 BLCC610I ...