SEC TION 1
Overview
F E AT U R E S
Listed below are the main features of the Solution 6000
Control Panel.
♦
Individual Box Tamper Circuit Monitoring
♦
Report Via Email (Internet)
♦
Telephone Line Busy Tone Detect
♦
RAS Intelli-Connect® CLI Caller Line Identification
♦
Daylight Savings
♦
Senior Watch
♦
System Maintenance Interval Reminder
♦
System Weekly Test Reminder
♦
Area Inactivity Interval
♦
Temporary PIN
♦
Dual Reporting
♦
Dual Redundant Reporting
♦
Alarm Report Abort/Cancel Options
♦
8 Programmable Holiday Calendars
♦
16 Programmable Door Assignments
♦
8 On-board Zones (Exp To 144 Zones)
♦
Fire Alarm Verification
♦
255 PIN Users
♦
4 Supervised High Power Digital Outputs
♦
1 Relay 2 Amp Form (C) Contact (Expandable to 32)
♦
Supervised Siren Driver
♦
Partitionable To 8 Areas
♦
Dialler Reports SIA, Contact ID, SMS and Email Formats
♦
Supervised LAN Keypads (Maximum 16 Keypads)
♦
Keyswitch Input
♦
1000 History Event Memory
♦
EMI / Lightning Transient Protection
♦
Fully Menu Text Programmable
♦
Programmable Via Solution Link Software (Remote/Direct)
♦
Telephone Line Fail Monitor
♦
Time Executed Functions
♦
60+ Output Event Types
♦
Exit Restart
♦
Expansion Module Supervision
♦
DTMF Tone Decoder Built In
♦
Remote Arming
O V E R V I E W
Zones
The Solution 6000 control panel provides up to 144
separate zones of protection. Zone programming
determines the panel’s response to open/short and
tamper conditions on the zone loop.
Areas
The control panel supports up to 8 separate areas. You
can assign all zones to a single area, or you can assign
each zone to a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Dialler
The control panel has a built-in dialler to send reports
to the receiving party (ie. Security company monitoring
station, mobile phone etc).
Keypads
You can connect a maximum of 16 fully supervised
keypads to the control panel. The available current affects
the total number of keypads that you can connect without
the need to provide additional power supplies.
History Log
The control panel can store up to 1000 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel’s history log via keypad,
serial printer (optional), or by connection of a personal
computer (direct/remote) using the Solution Link upload/
download software.
Programming
You can program the control panel either by a keypad
or using a personal computer using the Solution Link
upload/download software.