55
SV200 DC Hardware Manual
920-0126A
4/14/2017
NOTE:
• When power is applied, the drive’s display will show the customer defined monitoring mode. In factory default mode, it will display
the motor’s rotary velocity.
• When in parameter setting mode, pressing the
button will exit the parameter setting mode, and return back to parameter
selection mode, without saving any changes.
• When in parameter setting mode, pressing and holding the
button will confirm and apply the current parameter setting. This
will take effect immediately. However, this change will not save to drive’s flash memory. To save the parameter, go to function mode
, and then press and hold the
button.
• When the drive is connected to the host computer with SVX Servo Suite on, the parameter setting mode CANNOT be accessed
directly on the drive’s control panel.
5.3 LED display description
5.3.1 Decimal Point And Negative Sign Description
LED display
Description
negative
sign
motor enable
sign
Negative sign: when the value to be displayed
is a negative number ≥-9999, the highest digit
will display as a negative sign.
Decimal point: when the value to be displayed
is a negative number ≤-10000, a decimal point
will be displayed.
5.3.2 Parameter View Setting
LED display
Description
There are only 5 digits on the LED display, when a value with more than 5
digits needs to be displayed, it will be displayed in 2 segments.
When the highest digit of a value is flashing, it means only the lower 5
digits are shown. Press
to display the upper 5 digits.
The graph is displaying ‘-12802345’
5.3.3 Parameter Save Setting
LED display
Description
In parameter setting mode, pressing and holding the
button will
save the change. ‘Saved’ will also be displayed on the LED.
In parameter setting mode when the motor is rotating and the is pressed
and held, the LED display will read “busy” meaning that the current
parameter change cannot be saved. Stop the current motor motion and
save the parameter again.