7.1.3 CW/CCW limit
In order to prevent damage that might be caused by mechanical hardware accidentally moving out of range, it is highly recommended
that the CW/CCW position limits be configured by using external end-of-travel sensors connected to inputs X5 and X6.
P-64 (DL)
Description
Condition
Signal
Name
Function
1, 4
X5 sets CW limit
X6 sets CCW limit
Stops motion when X5/X6 is
closed
Closed
X5
Stops motion in CW direction, CW limit warning ON
X6
Stops motion in CCW direction, CCW limit warning ON
Open
X5
Rotates in CW direction as normal
X6
Rotates in CCW direction as normal
2, 5
X5 sets CW limit
X6 sets CCW limit
Stops motion when X5/X6 is open
Closed
X5
Rotates in CW direction as normal
X6
Rotates in CCW direction as normal
Open
X5
Stops motion in CW direction, CW limit warning ON
X6
Stops motion in CCW direction, CCW limit warning ON
3, 6, 13, 16 X5, X6 as general purpose input
(default)
7
X5 sets CW limit
Stops motion when X5 is closed
X6 as general purpose input
Closed
X5
Stops motion in CW direction, CW limit warning ON
Open
X5
Rotates in CW direction as normal
8
X5 sets CW limit
Stops motion when X5 is open
X6 as general purpose input
Closed
X5
Rotates in CW direction as normal
Open
X5
Stops motion in CW direction, CW limit warning ON
9
X6 sets CCW limit
Stops motion when X6 is closed
X5 as general purpose input
Closed
X6
Stops motion in CCW direction, CCW limit warning ON
Open
X6
Rotates in CCW direction as normal
10
X6 sets CCW limit
Stops motion when X6 is closed
X5 as general purpose input
Closed
X6
Rotates in CCW direction as normal
Open
X6
Stops motion in CCW direction, CCW limit warning ON
11, 13
X6 sets CW limit
X5 sets CCW limit
Stops motion when X5 is closed
Closed
X6
Stops motion in CCW direction, CCW limit warning ON
X5
Stops motion in CCW direction, CCW limit warning ON
Open
X6
Rotates in CW direction as normal
X5
Rotates in CCW direction as normal
12, 16
X6 sets CW limit
X5 sets CCW limit
Stops motion when X5 is open
Closed
X6
Rotates in CW direction as normal
X5
Rotates in CCW direction as normal
Open
X6
Stops motion in CW direction, CW limit warning ON
X5
Stops motion in CCW direction, CCW limit warning ON
17
X6 sets CW limit
Stops motion when X6 is closed
X5 as general purpose input
Closed
X6
Stops motion in CW direction, CW limit warning ON
Open
X6
Rotates in CW direction as normal
18
X6 sets CW limit
Stops motion when X6 is open
X5 as general purpose input
Closed
X6
Rotates in CW direction as normal
Open
X6
Stops motion in CW direction, CW limit warning ON
19
X5 sets CW limit
Stops motion when X5 is closed
X6 as general purpose input
Closed
X5
Stops motion in CCW direction, CCW limit warning ON
Open
X5
Rotates in CCW direction as normal
20
X5 sets CCW limit
Stops motion when X5 is open
X6 as general purpose input
Open
X5
Rotates in CCW direction as normal
Open