152
SV200 DC Hardware Manual
920-0126A
4/14/2017
9.3.7 Command Opcode Description
Register 40125 is defined as Command Opcode, when the following commands are entered into the register, the drive will execute the
corresponding operation.
1) SCL Command Encoding Table
SCL Command Encoding Table
Function
SCL
Opcode
Parameter 1
Parameter 2
Parameter 3
Parameter 4
Parameter 5
Alarm Reset
AX
0xBA
×
×
×
×
×
Start Jogging
CJ
0x96
×
×
×
×
×
Stop Jogging
SJ
0xD8
×
×
×
×
×
Encoder Function
EF
0xD6
0,1,2 or 6
×
×
×
×
Encoder Position
EP
0x98
Position
×
×
×
×
Feed to Double Sensor
FD
0x69
I/O Point 1
Condition 1
I/O Point 2
Condition 2
×
Follow Encoder
FE
0xCC
I/O Point
Condition
×
×
×
Feed to Length
FL
0x66
×
×
×
×
×
Feed to Sensor with Mask
Distance
FM
0x6A
I/O Point
Condition
×
×
×
Feed and Set Output
FO
0x68
I/O Point
Condition
×
×
×
Feed to Position
FP
0x67
×
×
×
×
×
Feed to Sensor
FS
0x6B
I/O Point
Condition
×
×
×
Feed to Sensor with Safety
Distance
FY
0x6C
I/O Point
Condition
×
×
×
Jog Disable
JD
0xA3
×
×
×
×
×
Jog Enable
JE
0xA2
×
×
×
×
×
Motor Disable
MD
0x9E
×
×
×
×
×
Motor Enable
ME
0x9F
×
×
×
×
×
Seek Home
SH
0x6E
I/O Point
Condition
×
×
×
Set Position
SP
0xA5
Position
×
×
×
×
Filter Input
FI
0xC0
I/O Point
Filter Time
×
×
×
Filter Select Inputs
FX
0xD3
×
×
×
×
×
Step Filter Freq
SF
0x06
Freq
×
×
×
×
Analog Deadband
AD
0xD2
0.001 V
×
×
×
×
Alarm Reset Input
AI
0x46
Function ('1'..'3')
I/O Point
×
×
×
Alarm Output
AO
0x47
Function ('1'..'3')
I/O Point
×
×
×
Analog Scaling
AS
0xD1
×
×
×
×
×
Define Limits
DL
0x42
1..3
×
×
×
×
Set Output
SO
0x8B
I/O Point
Condition
×
×
×
Wait for Input
WI
0x70
×
×
×
×
×
Queue Load & Execute
QX
0x78
1..12
×
×
×
×
Wait Time
WT
0x6F
0.01 sec
×
×
×
×
Stop Move, Kill Buffer
SK
0xE1
×
×
×
×
×
Stop Move, Kill Buffer
SKD
0xE2
×
×
×
×
×
For more detailed command functions description, please refer to the