136
SV200 DC Hardware Manual
920-0126A
4/14/2017
P-79 (DA)
RS-485 Address
Data Range
Default
Unit
LED Display
1 - 32
32
---
0
The individual drive address character for multi-drop RS-485/MODBUS communications. This command is not required for single-
axis (point-to-point) or RS-232 communications.
Modbus Address
SCL Address
Modbus Address
SCL Address
1
1
17
!
2
2
18
“
3
3
19
#
4
4
20
$
5
5
21
%
6
6
22
&
7
7
23
‘
8
8
24
(
9
9
25
)
10
:
26
*
11
;
27
+
12
<
28
,
13
=
29
-
14
>
30
.
15
?
31
/
16
@
32
0
P-80 (CO)
CANopen Node ID
Data Range
Default
Unit
LED Display
1 - 127
1
---
1
The CANopen NODE-ID for CANOpen type drives. Also used for IP address selection on Ethernet drives.
P-80(CO)
IP Address
P-80(CO)
IP Address
0
10.10.10.10
8
192.168.0.80
1
192.168.1.10
9
192.168.0.90
2
192.168.1.20
A
192.168.0.100
3
192.168.1.30
B
192.168.0.110
4
192.168.0.40
C
192.168.0.120
5
192.168.0.50
D
192.168.0.130
6
192.168.0.60
E
192.168.0.140
7
192.168.0.70
F
DHCP
P-81 (CB)
CANopen Baudrate
Data Range
Default
Unit
LED Display
0 - 7
0
---
0
CANopen drives support 8 settings for the baud rate.
Setting value
Baud rate
Setting value
Baud rate
0
1M
4
125K
1
800K
5
50K
2
500K
6
25K
3
250K
7
12.5K