108
SV200 DC Hardware Manual
920-0126A
4/14/2017
• Click Edit for detailed motion configurations.
7.5.1.2 Basic Configuration
Point Counts:
Select the number of position Point Counts: 7, 15, 31, or 63.
Position type:
There are two types of point-to-point motion: Relative Position and Absolute Positon.
The following graphs illustrate the difference between Rleative positioning and Absolute positioning. Example: Set the P1 position for
5 revs and the P2 position for 10 revs.
The difference between Relative Position and Absolute Position is shown below:
Position Unit:
Set Position Units as Counts or Lead.
•
Counts
represents the number of pulses from the encoder output. For Position Table mode, one motor revolution is 10000
pulse counts.
•
Lead
represents the distance for one motor revolution in units of mm/rev.