105
SV200 DC Hardware Manual
920-0126A
4/14/2017
7.4.3.7 Target Torque Reached
In torque mode, when the motor’s actual torque and commanded torque are the same, a “torque reached” output signal can be sent via
the Y3 output.
The first digit (from right to left) of parameter P-68 (MO) from the drive defines the output signal Y3.
Signal Name
PIN
P-68 (MO)
Condition
Function
Y3
Y3 (42)
OUT- (33)
□□□9
Closed
Closed means target torque not reached
Open
Open means output torque reached
□□□8
Closed
Close means output torque reach
Open
Open means target torque not reached
□□□3
(default)
General purpose signal, function disabled.
Parameter Settings
Parameter
Name
Data Range
Default
value
Unit
LED
Display
Description
P-87 (TV)
Torque within ripple
range, when torque
reached function
in use
0.00 - 3.00
0.00
A
0
When the actual torque output and the
commanded torque are the same, and within
the velocity ripple range the torque reached
output signal will be sent
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED display value = Torque ripple range X 100
Unit for torque ripple range is A (amps)
Setting Via Software