Low voltage
Drive voltage lower than 170VDC
1) Power supply voltage is low. Instantaneous
power failure has occurred
2) Lack of power capacity...Power supply
voltage has fallen down due to inrush current
at the main power-on.
3) Failure of servo driver (failure of the circuit)
1) Increase the power capacity. Change the
power supply.
2) Please check l1, l2, l3 power connections, please
refer to 4.1.5 P1 drive power connection.
3) please contact Applied Motion Products.
Q program is empty Drive in Q mode, but Q program is empty.
1. Please check Q program.
2. Please check operation mode correction.
3. Please check Q program coding, make sure no faults
to stop the program running.
Move when the
drive is disabled.
Motion command is received while motor is
disabled.
Please enable the motor, and send the command
again.