123
SV200 DC Hardware Manual
920-0126A
4/14/2017
LED
display
value
=
x 6
Where is target maximum acceleration/deceleration setting, Unit is rps/s.
P-22 (JS)
Jog velocity
Data Range
Default
Unit
LED Display
0.025 - 100
10
rps
2400
The speed for Jog moves in rev/sec.
NOTE:If you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 240
Where = is target velocity setting, Unit is rps (rev/sec) .
P-23 (JA)
Jog acceleration
Data Range
Default
Unit
LED Display
0.167 - 5000
100
rps/s
600
The accel/decel rate for Jog moves and velocity control mode in rev/sec/sec. Setting JA overwrites both the last JA and JL values. This
means that to have different jog accel and jog decel values, you should first send JA to set the jog accel and then send JL to set the jog
decel.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 6
Where is jog acceleration/deceleration setting, Unit is rps/s .
P-24 (JL)
Jog deceleration
Data Range
Default
Unit
LED Display
0.167 - 5000
100
rps/s
600
The accel/decel rate for Jog moves and velocity control mode in rev/sec/sec. Setting JA overwrites both the last JA and JL values. This
means that to have different jog accel and jog decel values, you should first send JA to set the jog accel and then send JL to set the jog
decel.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 6
Where is jog acceleration/deceleration setting, Unit is rps/s .
P-25 (VE)
Point to point Velocity
Data Range
Default
Unit
LED Display
0.025 - 100
5
rps
1200
The shaft speed for point-to-point move commands like FL, FP, FS, FD, SH, etc.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 240
Where = is target velocity setting, Unit is rps (rev/sec) .
P-26 (AC)
Point to point acceleration
Data Range
Default value
Unit
LED Display
0.167 - 5000
100
rps/s
600
The acceleration rate used in point-to-point move commands in rev/sec/sec.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 6
Where is point to point move acceleration setting, Unit is rps/s .